Datamax-oneil Class Series II Programmer’s Manual Manual do Utilizador Página 120

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 334
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 119
Extended System-Level Command Functions
106 Class Series 2 Programmer’s Manual
STX KH Dot Check (H-Class & M-Class Mark II only)
This command specifies dot check operations for the printhead elements.
Syntax:
<
STX>KHx
<
CR
>
Where:
x
- Specifies the operation, where:
P = Performs dot check;
A = Returns the most recent dot check and dot
resistance results; and,
B = Returns the most recent dot check failed dot
results.
Sample:
<STX>KHP<CR>
The sample above performs dot check with DOTCHECK and a
progress bar displayed.
Sample:
<STX>KHA<CR>
The sample above returns results from the last dot check for
every element and its resistance up to 1350 ohms [with out of
range (bad or suspect) values indicates as ******], the number
of dots tested, the total number of bad or suspect dots detected
and, the minimum, maximum, and average resistance
and variance:
DOTCHECK RESULTS
DOTS TESTED GOOD 830 OF 832
DOT OHMS
0 1148
1 1148
2 1140
.
.
.
142 1199
143 *****
144 *****
145 1050
.
.
.
830 1116
831 1116
832 1116
TOTAL BAD DOTS: 2
MIN MAX AVG VAR
921 1640 1125 719
Vista de página 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 333 334

Comentários a estes Manuais

Sem comentários