Extended System-Level Command Functions
100 Class Series 2 Programmer’s Manual
Value Parameter WiFi Interpretation Default Value
M x
Is the maximum transmission rate,
where x:
0 = 1 Mbps
1 = 2 Mbps
2 = 5.5 Mbps
3 = 11 Mbps
2
N y
Is the client name, where:
y = Up to 31 characters, no spaces
N/A
P x
Is the WEP Access Point Density, where
x:
0 = Low
1= Medium
2 = High
0
R y
Is the Region, where:
y = Two-character code; see Appendix T.
US
T x
Is the Mode, where x:
0 = Adhoc
1 = Infrastructure
2 = Unique (SSID = MAC address; and,
WiFi type = Adhoc)
2
V x
Is the DHCP Retransmit Interval, where:
x = 1 to 64 seconds
15
X a
Is MAC Cloning, where a:
0 = Disable
1 = Enable
0
* Each octet must be zero-filled to be properly interpreted (e.g., an IP Address of
10.12.0.243 must be sent to the printer as 010.012.000.243).
Table 5-13 WiFi Setup
Example 1:
<STX>KcNTDN;NTwN;WEI010.012.000.248;WEAEngWAN1;NTI010.012.000.245;NTS25
5.255.000.000;NTG010.012.254.254<CR>