3 | Connections and Setup
Performance Series User’s Guide 48
Note: If the ripples are vertically straight, advance to step 12 to adjust the ribbon shield.
Figure: 3 - 32 Supply Side Inspection
7. If excessive ripples exist, loosen the 3mm cam roller hex head screw enough to
allow the cam roller to spin.
Figure: 3 - 33 Cam Roller
8. Turn the cam roller adjuster until the ripples are either gone or are vertical.
Cam Roller
Screw
Cam Roller
Adjuster